;========================================================== ; GSD-File for EM600 ; ; Auto_Baud_supp, 12MBaud ; ; Stand : ; File : Sinee.GSD ;=========================================================== #Profibus_DP ; Unit-Definition-List: GSD_Revision = 1 Vendor_Name="SINEE" Model_Name = "EC-CM-P1" Revision = "Rev. 1" Ident_Number = 0x0656 Protocol_Ident = 0 ; PROFIBUS DP Station_Type = 0 ; DP-slave FMS_supp = 0 Hardware_Release = "V1.0" Software_Release = "V1.0" Redundancy = 0 Repeater_Ctrl_Sig = 2 ; TTL 24V_Pins = 0 Implementation_Type = "SPC3" Bitmap_Device = "VFDDRV" Bitmap_Diag = "VFDDRV" Bitmap_SF = "VFDDRV" Slave_Family = 1@TdF@SINEE VFD Drives; Drives family ; Supported Communication Speeds: Auto_Baud_supp = 1 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 ; DP_Slave Information: Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 1 ; 100 micro-second ; Module-Definitions: Modular_Station = 1 ; 0-compact; 1-modular Max_Module = 1 Max_Input_Len = 60 Max_Output_Len = 60 Max_Data_Len = 120 Modul_Offset = 0 Fail_Safe = 0 Max_Diag_Data_Len = 7 ;zr modify ok ;specify the user parameters: Max_User_Prm_Data_Len = 59 User_Prm_Data_Len = 59 User_Prm_Data = 0x00,0x00,0x00,\ 0x20,0x00,\ 0x20,0x01,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x21,0x01,\ 0x21,0x02,\ 0x21,0x03,\ 0x21,0x04,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x00,\ 0x00,0x02,\ 0x00,0x02,\ 0x00,0x01,\ 0x00,0x00 ;type modify ok zr Module = "4 PKW, 2 PZD (PPO 1) " 0xF3, 0xF1 EndModule Module = "4 PKW, 6 PZD (PPO 2) " 0xF3, 0xF5 EndModule Module = "0 PKW, 2 PZD (PPO 3) " 0x00, 0xF1 EndModule Module = "0 PKW, 6 PZD (PPO 4) " 0x00, 0xF5 EndModule Module = "4 PKW, 12 PZD (PPO 5) " 0xF3, 0xFB EndModule ; Extended Description of User-Parameters PrmText = 1 Text(0) = "Ignore and Continue" Text(1) = "Stop accord to Pr.STOP METHOD" EndPrmText PrmText = 2 Text(0) = "Stop DataExchange & Report Fault" Text(1) = "Continue & Report Alarm" Text(2) = "Ignore & Continue DataExchange" EndPrmText ExtUserPrmData = 1 "Data Output 1( control word)" Unsigned16 28672 28672-28672 EndExtUserPrmData ExtUserPrmData = 2 "Data Output 2" Unsigned16 28673 0-65535 EndExtUserPrmData ExtUserPrmData = 3 "Data Output 3" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 4 "Data Output 4" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 5 "Data Output 5" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 6 "Data Output 6" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 7 "Data Output 7" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 8 "Data Output 8" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 9 "Data Output 9" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 10 "Data Output 10" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 11 "Data Output 11" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 12 "Data Output 12" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 13 "Data Input 1(status word)" Unsigned16 29184 29184-29184 EndExtUserPrmData ExtUserPrmData = 14 "Data Input 2" Unsigned16 4608 0-65535 EndExtUserPrmData ExtUserPrmData = 15 "Data Input 3" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 16 "Data Input 4" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 17 "Data Input 5" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 18 "Data Input 6" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 19 "Data Input 7" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 20 "Data Input 8" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 21 "Data Input 9" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 22 "Data Input 10" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 23 "Data Input 11" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 24 "Data Input 12" Unsigned16 0 0-65535 EndExtUserPrmData ExtUserPrmData = 25 "dout_len" Unsigned16 2 0-10 EndExtUserPrmData ExtUserPrmData = 26 "din_len" Unsigned16 2 0-10 EndExtUserPrmData ExtUserPrmData = 27 "baudrate" Unsigned16 5 1-5 EndExtUserPrmData ExtUserPrmData = 28 "Reserve" Unsigned16 0 0-2 EndExtUserPrmData Ext_User_Prm_Data_Ref(3) = 1 Ext_User_Prm_Data_Ref(5) = 2 Ext_User_Prm_Data_Ref(7) = 3 Ext_User_Prm_Data_Ref(9) = 4 Ext_User_Prm_Data_Ref(11) = 5 Ext_User_Prm_Data_Ref(13) = 6 Ext_User_Prm_Data_Ref(15) = 7 Ext_User_Prm_Data_Ref(17) = 8 Ext_User_Prm_Data_Ref(19) = 9 Ext_User_Prm_Data_Ref(21) = 10 Ext_User_Prm_Data_Ref(23) = 11 Ext_User_Prm_Data_Ref(25) = 12 Ext_User_Prm_Data_Ref(27) = 13 Ext_User_Prm_Data_Ref(29) = 14 Ext_User_Prm_Data_Ref(31) = 15 Ext_User_Prm_Data_Ref(33) = 16 Ext_User_Prm_Data_Ref(35) = 17 Ext_User_Prm_Data_Ref(37) = 18 Ext_User_Prm_Data_Ref(39) = 19 Ext_User_Prm_Data_Ref(41) = 20 Ext_User_Prm_Data_Ref(43) = 21 Ext_User_Prm_Data_Ref(45) = 22 Ext_User_Prm_Data_Ref(47) = 23 Ext_User_Prm_Data_Ref(49) = 24 Ext_User_Prm_Data_Ref(51) = 25 Ext_User_Prm_Data_Ref(53) = 26 Ext_User_Prm_Data_Ref(55) = 27 Ext_User_Prm_Data_Ref(57) = 28 ;============ END of GSD file for VFD Drives =====================